Advanced Transient Response Tests

For details on our transient response testing, please click here.

These tests are crucial because they simulate the transient loads a PSU is likely to handle (such as booting a RAID array or an instant 100 percent load of CPU/GPUs). We call these “Advanced Transient Response Tests” and they are designed to be very tough to master, especially for a PSU with a capacity of less than 500W.

In all of the tests, we use an oscilloscope to measure the voltage drops caused by the transient load. The voltages should remain within the ATX specification's regulation limits.

We should note that the ATX spec requires for capacitive loading during the transient rests, but in our methodology we chose to apply the worst case scenario with no extra capacitance on the rails.

Advanced Transient Response at 20 Percent – 200ms

Voltage Before After Change Pass/Fail
12V 12.087V 11.990V 0.80% Pass
5V 5.051V 4.951V 1.98% Pass
3.3V 3.352V 3.258V 2.80% Pass
5VSB 5.004V 4.942V 1.24% Pass

Advanced Transient Response at 20 Percent – 20ms

Voltage Before After Change Pass/Fail
12V 12.083V 11.941V 1.18% Pass
5V 5.051V 4.941V 2.18% Pass
3.3V 3.351V 3.238V 3.37% Pass
5VSB 5.004V 4.945V 1.18% Pass

Advanced Transient Response at 20 Percent – 1ms

Voltage Before After Change Pass/Fail
12V 12.083V 11.957V 1.04% Pass
5V 5.051V 4.941V 2.18% Pass
3.3V 3.351V 3.237V 3.40% Pass
5VSB 5.004V 4.949V 1.10% Pass

Advanced Transient Response at 50 Percent – 200ms

Voltage Before After Change Pass/Fail
12V 12.077V 11.915V 1.34% Pass
5V 5.047V 4.942V 2.08% Pass
3.3V 3.345V 3.245V 2.99% Pass
5VSB 4.984V 4.922V 1.24% Pass

Advanced Transient Response at 50 Percent – 20ms

Voltage Before After Change Pass/Fail
12V 12.075V 11.833V 2.00% Pass
5V 5.047V 4.927V 2.38% Pass
3.3V 3.345V 3.231V 3.41% Pass
5VSB 4.984V 4.921V 1.26% Pass

Advanced Transient Response at 50 Percent – 1ms

Voltage Before After Change Pass/Fail
12V 12.075V 11.935V 1.16% Pass
5V 5.046V 4.928V 2.34% Pass
3.3V 3.344V 3.229V 3.44% Pass
5VSB 4.984V 4.932V 1.04% Pass


The transient response is good at +12V, for the standards of the SFX category, and quite good on the rest rails. Nonetheless, the gold SF600 unit registers lower deviations on the minor rails.

Here are the oscilloscope screenshots we took during Advanced Transient Response Testing:

Transient Response At 20 Percent Load – 200ms

Transient Response At 20 Percent Load – 20ms

Transient Response At 20 Percent Load – 1ms

Transient Response At 50 Percent Load – 200ms

Transient Response At 50 Percent Load – 20ms

Transient Response At 50 Percent Load – 1ms

Turn-On Transient Tests

In the next set of tests, we measure the unit’s response in simpler transient load scenarios—during its power-on phase.

For our first measurement, we turn the PSU off, dial in the maximum current the 5VSB rail can handle, and switch the PSU back on.

In the second test, we dial the maximum load the +12V rail can handle and start the PSU while it is in standby mode. In the last test, while the PSU is completely switched off (we cut off the power or switch the PSU off through its power switch), we dial the maximum load the +12V rail can handle before restoring power. The ATX specification states that recorded spikes on all rails should not exceed 10 percent of their nominal values (+10 percent for 12V is 13.2V, and 5.5V for 5V).


There are no notable spikes and voltage overshoots during the first two tests, however in the last test we notice a region with increased ripple at +12V.