Home / Tech News / Featured Tech Reviews / Kolink Continuum KL-C1050PL 1050W Platinum Review

Kolink Continuum KL-C1050PL 1050W Platinum Review

Correctly testing power supplies is a complex procedure and KitGuru have configured a test bench which can deliver up to a 2,000 watt DC load. We test ambient temperatures at 35c in our environment to greater reflect warmer internal chassis conditions.

We use combinations of the following hardware:

• SunMoon SM-268
• CSI3710A Programmable DC load (+3.3V and +5V outputs)
• CSI3711A Programmable DC load (+12V1, +12V2, +12V3, and +12V4)
• Extech Power Analyzer
• Extech MultiMaster MM570 digital multimeter
• SkyTronic DSL 2 Digital Sound Level Meter (6-130dBa)
• Digital oscilloscope (20M S/s with 12 Bit ADC)
• Variable Autotransformer, 1.4 KVA

DC Output Load Regulation

Combined

DC Load

+3.3V
+5V
+12V
+5VSB
-12V
A
V
A
V
A
V
A
V
A V
105W
0.87
3.33
0.96
5.02
7.68
12.02
0.50
5.02
0.20
-12.03
210W
1.60
3.33
1.63
5.02
15.75
12.02
1.00
5.02
0.20
-12.04
525W
3.00
3.32
3.14
5.02
40.68
12.01
1.50
5.01
0.30
-12.04
788W
4.00
3.32
4.14
5.01
61.66
12.00
2.00
5.00
0.30
-12.04
10500W
5.00
3.31
5.25
5.01
82.46
11.97
2.50
5.00
0.50
-12.05

Load regulation is very strong indeed, holding within 1.5%

Kolink Continuum KL-C1050PL
Maximum Load
1177W

We managed to get another 127W from the power supply before the protection circuitry kicked in. The supply was undamaged and it was ready to fire up again when we dropped the load to a more realistic level.

Next we want to try Cross Loading. This basically means loads which are not balanced. If a PC for instance needs 500W on the +12V outputs but something like 30W via the combined 3.3V and +5V outputs then the voltage regulation can fluctuate badly.

Cross Load Testing +3.3V +5V +12V -12V +5VSB
A V A V A V A V A V
885W 2.0 3.34 2.0 5.02 72.0 11.95 0.2 -12.04 0.50 5.02
240W 20.0 3.30 24.0 4.97 2.0 12.02 0.2 -12.03 0.50 5.01

The Kolink Continuum KL-C1050PL power supply delivered a strong set of results in the demanding Cross load test, as shown above.

We then used an oscilloscope to measure AC ripple and noise present on the DC outputs. We set the oscilloscope time base to check for AC ripple at both high and low ends of the spectrum. ATX12V V2.2 specification for DC output ripple and noise is defined in the ATX 12V power supply design guide.

ATX12V Ver 2.2 Noise/Ripple Tolerance
Output
Ripple (mV p-p)
+3.3V
50
+5V
50
+12V1
120
+12V2
120
-12V
120
+5VSB
50

Obviously when measuring AC noise and ripple on the DC outputs the cleaner (less recorded) means we have a better end result. We measured this AC signal amplitude to see how closely the unit complied with the ATX standard.

AC Ripple (mV p-p)
DC Load +3.3V +5V +12V 5VSB
100W 5 10 10 5
200W 10 10 10 5
400W 10 10 15 5
600W 10 15 20 5
800W 15 15 25 10
1050W 15 15 30 10

Ripple suppression is excellent. All rails held well within the rated industry parameters. The +12V rail peaked around 30mV which is a very good result indeed.

Efficiency (%)
100W
85.2
200W
88.9
300W
93.0
500W
94.1
800W
93.2
1050W 92.0

The overall efficiency results are excellent, peaking at 94% at 500W. This drops close to 92% efficiency at full load, a very impressive result.

We take the issue of noise very seriously at KitGuru and this is why we have built a special home brew system as a reference point when we test noise levels of various components. Why do this? Well this means we can eliminate secondary noise pollution in the test room and concentrate on components we are testing. It also brings us slightly closer to industry standards, such as DIN 45635.

Today to test the Power Supply we have taken it into our acoustics room environment and have set our SkyTronic DSL 2 Digital Sound Level Meter (6-130dBa) one meter away from the unit. We have no other fans running so we can effectively measure just the noise from the unit itself.

As this can be a little confusing for people, here are various dBa ratings in with real world situations to help describe the various levels.

KitGuru noise guide

10dBA – Normal Breathing/Rustling Leaves
20-25dBA – Whisper
30dBA – High Quality Computer fan
40dBA – A Bubbling Brook, or a Refrigerator
50dBA – Normal Conversation
60dBA – Laughter
70dBA – Vacuum Cleaner or Hairdryer
80dBA – City Traffic or a Garbage Disposal
90dBA – Motorcycle or Lawnmower
100dBA – MP3 Player at maximum output
110dBA – Orchestra
120dBA – Front row rock concert/Jet Engine
130dBA – Threshold of Pain
140dBA – Military Jet takeoff/Gunshot (close range)
160dBA – Instant Perforation of eardrum

Noise (dBA)
100W
<28.0
200W
<28.0
400W
30.4
600W
32.3
800W 33.1
1050W 35.4

Under normal conditions, the Kolink Continuum KL-C1050PL is actually a reasonably quiet power supply. The fan doesn't spin that fast until the load demand hits a sustained 800 watts or greater. At full load, we measured 35.4dBA which is clearly audible . The fan pitch is quite low which helps mask the noise a little inside a normal system build.

Temperature (c)
Intake
Exhaust
100W
35
38
200W
35
41
400W
37
46
650W
44
52
800W
46
56
1050W 51 64

Temperatures are well controlled as the fan spins actively once load hits 700W load and beyond.

Maximum load
Efficiency
1177W
91.6

Pushing the power supply above its rated limits generates an efficiency level of around 91.6%. This is not a viable ‘real world’ situation, but its interesting nonetheless.

Become a Patron!

Check Also

Geekom A7 Mini PC Review (Ryzen 9 7940HS)

A Ryzen 9 7940HS and 32GB of DDR5 memory in a 0.47L chassis